Friday, December 4, 2015
UL Requires New Holographic Labels for Communications Cable
To further enhance the integrity of the UL Mark, UL is introducing a holographic label requirement for a wide variety of cable categories. The new UL Marks include the use of secure golden holographic label material and color shifting inks to prevent unauthorized label reproduction.
This type of label has been proven an effective tool in deterring counterfeit products from entering the marketplace. Effective October 1, 2010 manufacturers will be required to apply holographic UL Marks for the products noted below. Although the holographic label is new, the remaining engineering marking information provided on the cable tags or reels and the methods for applying these markings remain unchanged.
• Communications Cable (DUZX/DUZX7)
• Communications Cable Verified to UL Performance Category Program (DUZX)
• Data Transmission Cable Verified in Accordance With National or International Specifications (DVBI)
• Community Antenna Television Cable (DVCS)
• Data Processing Cable (EMRB)
• Non-Power-Limited Fire-Alarm Cable (HNHT)
• Power-Limited Fire-Alarm Cable (HNIR / HNIR7)
• Instrumentation Tray Cable (NYTT)
• Network Powered Broadband Communications Cable (PWIP)
• Optical Fiber Cable (QAYK/QAYK7)
• Power Limited Circuit Cable (QPTZ)
Code authorities have already begun to see cables with the new holographic labels during their inspections, and will see an increasing number of cables with these markings in the future. You can expect to see the UL symbol on the product and the new holographic UL Listing Mark on the attached tag, the reel, or the smallest unit container in which the cable is packaged. The UL symbol will still appear on the surface print of the cable, and can be either the complete UL in a circle, or the letters “UL” in parenthesis “(UL)”. Surface printing of the UL Certification Mark on the wire insulation or jacketed material is only permissible when the accompanying reel or smallest unit container is also provided with the UL holographic Listing Mark. Although manufacturers cannot add non-holographic labels to cable after October 1, 2010, it may take a while for cable with the non-holographic Listing Marks to be cleared from the supply chain.
An example of the UL holographic label on Cat5e Bulk Communications Cable offered at Discount-Low-Voltage.com
Related Posts:
UL Warns About Counterfeit Communications Cable
UL Finds Performance & Safety Issues Found in Offshore Communications Cable
How Low Voltage Communications Cable is Made - Cat3, Cat5e, Cat6, OSP
25 Pair Cat3 Telephone Communications Cable Video
What is Plenum Communications Cable and When Should I use It
How To Make an Ethernet Cat5e/Cat6 Cable
Interlocking Armored Fiber Optic Cable Video
Related Posts:
Interlock Armored Fiber Optic Cable or Non-Armored Fiber in Innerduct?
Pulling Fiber Optic Cable
How It's Made: Fiber Optic Cable
How To Install Fiber Optic Fan Out Kit for Loose Tube Fiber
Difference Between: Loose Tube Fiber and Tight Buffered Fiber
How To Terminate Fiber Optic Cable Using AFL FAST Connectors
Belden 1532A Direct Burial RG6 Coax Cable Video
As always, we've been busy making product videos for you. Today's video features a direct burial RG6 cable by Belden. This RG6 coax cable is used primarily for CATV installations, and is perfect if you have a satellite dish in your backyard, or anywhere not attached to the house. You can order this cable in 250ft, 500ft, 750ft or 1,000ft. To order, click the link above or visit Discount-Low-Voltage.com
Belden Part # 1532A
Read more »
Belden Part # 1532A
New Videos - Bulk Cat5e Cable at Discount-Low-Voltage.com
Check out the new product videos we did on Bulk Cat5e cable and Cat5e Shielded Cable. The cat5e cable comes in 1,000ft pull boxes and features the Reelex cone inside. These Reelex boxes reduce tangles while pulling cable, which increases your productivity. The shielded cat5e cable comes on a durable wooden spool. For more information on both products, click the links above or visit Discount-Low-Voltage.com.
Related Posts:
Bulk Cat5e Cable Details
How To Make an Ethernet Cat5e/Cat6 Patch Cable
Standard 568b Wiring Diagram
Crazy Cat5e Wiring - INSANE!!!
How It's Made - Cat5e Low Voltage Cable Video
Bulk Cat5e Cable Video
Bulk Cat5e Shielded Cable
Related Posts:
Bulk Cat5e Cable Details
How To Make an Ethernet Cat5e/Cat6 Patch Cable
Standard 568b Wiring Diagram
Crazy Cat5e Wiring - INSANE!!!
How It's Made - Cat5e Low Voltage Cable Video
100 Pair Cat3 Telephone Cable Video
Here's our 100 pair category 3 telephone cable for indoor use. This cable is cut per foot, so you can order any length between 1 and 1,000 feet. We also have it available with a plenum rated jacket, for use in air handling spaces in accordance with Fire & Safety Code. Smaller pair counts are available online, as low as 4 pairs. If you need more than 100 pair cable, please contact us for a quote.
To order, click the link above or visit Discount-Low-Voltage.com
Related Posts:
How 100 Pair Low Voltage Cable is Made
25 Pair Cat3 Telephone Cable Video
25 Pair Color Code Chart
100 Pair PE22 Aerial Telephone Cable
Read more »
To order, click the link above or visit Discount-Low-Voltage.com
Related Posts:
How 100 Pair Low Voltage Cable is Made
25 Pair Cat3 Telephone Cable Video
25 Pair Color Code Chart
100 Pair PE22 Aerial Telephone Cable
500ft Bulk Cat5e Cable - Bravo Paks
The 500ft Bulk Cat5e Bravo Pak is the star of this weeks Product Video Blog.
This 500ft bulk cat5e cable works great with:
- The Kwik Jack System
- Dynacom Cat5e 110 Patch Panels
- RJ45 Modular Plugs
Watch the Video!
Features and Benefits of the 500ft Bulk Cat5e Bravo Pak Cable:
- Short 500ft length for small jobs
- Less Waste
- Easy to pull, never kinks
- UL Listed and RoHS Compliant
- Great for making custom length ethernet patch cords
- In stock now!
- Easy to order from Discount-Low-Voltage.com
- More...
Related Posts:
Interlock Armored Fiber Optic Cable or Non-Armored Fiber With Innerduct?
Fiber Optic Cable Installation:
Fiber optic cable is a great investment to any infrastructure, providing superior performance at much longer distances than traditional copper networks. When installing fiber optic cable, there's many factors to take into consideration. One of the most important, is how to protect your investment. Two of the most common routes to take are installing an innerduct, or buying fiber that has a layer of protection built in. Both have their pro's and con's, so lets take a look at each.
Fiber Optic Cable Installed in Innerduct:
Innerduct is a corrugated tube that surrounds your fiber optic cable giving it protection and acts as a pathway for the fiber to be pulled through. Innerduct comes in HDPE for outdoor use, PVC for indoor use and PLENUM for indoor use in plenum air spaces. Although innerduct is a great way to protect your fiber, it requires an extra step. This can result in higher labor costs, materials costs and possible additional equipment and freight fees. Long lengths of innerduct require very large wooden spools to be put on, which can be costly to ship and work with. Once the innerduct is installed, you proceed as usual: run your fiber optic cable, terminate and test it. Wouldn't it be easier if you could just run fiber and remove the innerduct step altogether? You can... keep reading.
Interlock Armored Fiber Optic Cable:
Interlock armored fiber cable is a great alternative to installing innerduct. Interlocking Armored Riser Cables are standard cables placed inside a spirally-wrapped aluminum interlocking armor for ruggedness and superior crush resistance. Designed for use in riser and general purpose environments for intrabuilding backbone and horizontal installations, these multifiber cables use individually jacketed TBII® Buffered Fibers enabling easy, consistent stripping and facilitating termination. This core is protected by a flexible, spiral-wrapped, aluminum interlocking armor that offers over seven times the crush protection compared to unarmored cables and easy one-step installation. With a flame-retardant outer jacket, this cable is particularly useful for heavy traffic or more challenging mechanical exposure conditions and applications requiring extra rugged cables. Interlocking armored fiber does have it's downfalls though. Future additions: when installing innerduct, you can reuse the cabling pathway to replace the fiber, or add additional fibers if you have extra space. This is a great way to maximize your investment. Without that innerduct installed, you will be starting the process all over again from the beginning. Pricing is also a concern. Interlock armored fiber is typically 3 times as expensive as regular non-armored fiber.
Here's a quick look at one of these cables from our YouTube Channel.
Tips:
- Always install the correct fiber and innerduct based on your buildings fire safety codes
- Future proof your installation if possible. Install a larger innerduct than needed or buy an interlocking armored fiber with additional strands of fiber.
- Pre Terminated Fiber Cable: Can cut fiber installation by 75%. This is a great option for beginners or long time fiber installers. Pre terminated fiber is custom made to your exact specs, comes with a pulling eye for easy installation and includes test results.
Related Articles:
Pulling Fiber Optic Cable
How It's Made: Fiber Optic Cable
How To Install Fiber Optic Fan Out Kit for Loose Tube Fiber
Difference Between: Loose Tube Fiber and Tight Buffered Fiber
How To Terminate Fiber Optic Cable Using AFL FAST Connectors
"By Mercy Salinas"
Fiber optic cable is a great investment to any infrastructure, providing superior performance at much longer distances than traditional copper networks. When installing fiber optic cable, there's many factors to take into consideration. One of the most important, is how to protect your investment. Two of the most common routes to take are installing an innerduct, or buying fiber that has a layer of protection built in. Both have their pro's and con's, so lets take a look at each.
Fiber Optic Cable Installed in Innerduct:
Innerduct is a corrugated tube that surrounds your fiber optic cable giving it protection and acts as a pathway for the fiber to be pulled through. Innerduct comes in HDPE for outdoor use, PVC for indoor use and PLENUM for indoor use in plenum air spaces. Although innerduct is a great way to protect your fiber, it requires an extra step. This can result in higher labor costs, materials costs and possible additional equipment and freight fees. Long lengths of innerduct require very large wooden spools to be put on, which can be costly to ship and work with. Once the innerduct is installed, you proceed as usual: run your fiber optic cable, terminate and test it. Wouldn't it be easier if you could just run fiber and remove the innerduct step altogether? You can... keep reading.
Interlock Armored Fiber Optic Cable:
Interlock armored fiber cable is a great alternative to installing innerduct. Interlocking Armored Riser Cables are standard cables placed inside a spirally-wrapped aluminum interlocking armor for ruggedness and superior crush resistance. Designed for use in riser and general purpose environments for intrabuilding backbone and horizontal installations, these multifiber cables use individually jacketed TBII® Buffered Fibers enabling easy, consistent stripping and facilitating termination. This core is protected by a flexible, spiral-wrapped, aluminum interlocking armor that offers over seven times the crush protection compared to unarmored cables and easy one-step installation. With a flame-retardant outer jacket, this cable is particularly useful for heavy traffic or more challenging mechanical exposure conditions and applications requiring extra rugged cables. Interlocking armored fiber does have it's downfalls though. Future additions: when installing innerduct, you can reuse the cabling pathway to replace the fiber, or add additional fibers if you have extra space. This is a great way to maximize your investment. Without that innerduct installed, you will be starting the process all over again from the beginning. Pricing is also a concern. Interlock armored fiber is typically 3 times as expensive as regular non-armored fiber.
Here's a quick look at one of these cables from our YouTube Channel.
Tips:
- Always install the correct fiber and innerduct based on your buildings fire safety codes
- Future proof your installation if possible. Install a larger innerduct than needed or buy an interlocking armored fiber with additional strands of fiber.
- Pre Terminated Fiber Cable: Can cut fiber installation by 75%. This is a great option for beginners or long time fiber installers. Pre terminated fiber is custom made to your exact specs, comes with a pulling eye for easy installation and includes test results.
Related Articles:
Pulling Fiber Optic Cable
How It's Made: Fiber Optic Cable
How To Install Fiber Optic Fan Out Kit for Loose Tube Fiber
Difference Between: Loose Tube Fiber and Tight Buffered Fiber
How To Terminate Fiber Optic Cable Using AFL FAST Connectors
"By Mercy Salinas"
Bulk Cat5e 25 Pair Indoor/Outdoor Cable Video
Features and Benefits of the Superior Essex Cat5e 25 Pair Cable:
- Made in the USA
- Allows installation at -20°C temperatures
- Small outside diameter
- Capable of 1000BASE-T
- Black, CM rated, non-haolgen, OSP grade jacket material
- Vibrant insulation colors
- Compliant to ANSI/TIA-568-C.2 for CAT 5e
- Easy to order from Discount-Low-Voltage.com
- More...
Related Posts:
100 Pair Aerial Telephone Cable Video
100 Pair Aerial/Duct Category 3 Telephone Cable for Outdoor Use
Let's take a look at what the 100 pair aerial telephone cable looks like. As you can see, this is a very thick and strong cable, with an outside diameter of 0.88". The 24AWG durable black jacket us UV and weather resistant. Underneath the jacket is a corrugated 0.008" aluminum tape and plastic coating for superior protection.
Features:
- USA Made
- General Cable part # 7527161
- 100 Pair
- 24 AWG (American Wire Gauge)
- PE22 Rated for Aerial/Duct
- UV Resistant Jacket
- Corrugated Aluminum Tape
Note: We recommend using a PE89 cable for direct burial use. The PE89 features a water blocking gel for supreme protection against the elements.
To order, click the link above, or visit Discount-Low-Voltage.com
12 Pair Direct Burial Telephone Cable Video
12 Pair direct burial telephone cable is suitable for outdoor applications without the use of conduit. The cable is filled with water resistant gel and a UV resistant jacket. The conductors are 24awg and follow the industry standard color code for twisted pair cables. Direct burial telephone cable must not be run for more than 50ft inside buildings (per the National Electrical Code). Let's take a look at what the 12 pair PE89 direct burial telephone cable looks like.
Specifications:
Core Construction:
- Solid, annealed copper; size 24 AWG
Insulation:
- Dual insulation consisting of an inner layer of foamed polyolefin surrounded by a solid polyolefin skin, color-coded in accordance with telephone industry standards
Twisted Pairs:
- Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk
Core Assembly:
- 25 pairs and less: pairs are assembled together in a single group
- More than 25 pairs: pairs are arranged in groups, each group having a color coded unit binder
Filling Compound:
- The entire core assembly is completely filled with ETPR compound, filling the interstices between the pairs and under the core tape
Core Wrap:
- Non-hygroscopic dielectric tape applied longitudinally with an overlap
Aluminum Shield:
- Corrugated, copolymer-coated, 0.008" aluminum tape applied longitudinally with an overlap
- The sheath interfaces are flooded with an adhesive water-blocking compound
Jacket:
- Black, linear low density polyethylene Application(s):
- Intended for duct and direct buried installations where protection against water and moisture entry is required and may also be installed aerially
Compliance:
- Rural Development Utility Program(RDUP) 7 CFR 1755.890 (RUS PE-89)
For pricing, visit 12 Pair PE89 Underground Telephone Wire
Related Posts:
25 Pair Direct Burial Telephone Cable
Cat5e 4 Pair Direct Burial Wire
Video - How Low Voltage Direct Burial Cable is Made
Specifications:
Core Construction:
- Solid, annealed copper; size 24 AWG
Insulation:
- Dual insulation consisting of an inner layer of foamed polyolefin surrounded by a solid polyolefin skin, color-coded in accordance with telephone industry standards
Twisted Pairs:
- Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk
Core Assembly:
- 25 pairs and less: pairs are assembled together in a single group
- More than 25 pairs: pairs are arranged in groups, each group having a color coded unit binder
Filling Compound:
- The entire core assembly is completely filled with ETPR compound, filling the interstices between the pairs and under the core tape
Core Wrap:
- Non-hygroscopic dielectric tape applied longitudinally with an overlap
Aluminum Shield:
- Corrugated, copolymer-coated, 0.008" aluminum tape applied longitudinally with an overlap
- The sheath interfaces are flooded with an adhesive water-blocking compound
Jacket:
- Black, linear low density polyethylene Application(s):
- Intended for duct and direct buried installations where protection against water and moisture entry is required and may also be installed aerially
Compliance:
- Rural Development Utility Program(RDUP) 7 CFR 1755.890 (RUS PE-89)
For pricing, visit 12 Pair PE89 Underground Telephone Wire
Related Posts:
25 Pair Direct Burial Telephone Cable
Cat5e 4 Pair Direct Burial Wire
Video - How Low Voltage Direct Burial Cable is Made
What is Plenum Cable/Innerduct and When Do I Use it?
What is Plenum?
According to the National Electric Code (NEC) a plenum is a "compartment or chamber to which one or more air ducts are connected and [which] forms part of the air distribution system." To qualify as a plenum, the space above an acoustic tile ceiling would have to extend above other rooms in the same building or be open to ducts connecting it to other parts of the building. The concern is that during a fire, if there is burning material in a plenum air space, smoke and fumes can travel through air ducts to the whole building. For this reason, there are codes to restrict the types of materials (such as wiring) that can be placed in the plenum.
It's quite common to have an acoustic tile ceiling without having a plenum. If your room-dividing walls extend above the dropped ceiling and seal off the space above, you do not have a plenum air space and so may not require plenum-rated wires. You can lift up an acoustical tile in your room and peek in to see if your room has a plenum.
What is the code?
According to the National Electric Code (NEC), in plenum air spaces you must use plenum rated cables, also called Communications Plenum Cable (CMP). Plenum cable is only required when cable is installed in a plenum air space. Materials kept below the ceiling — including speaker wire, computer cables, telephone cords, etc. — do not need to be plenum rated according to the NEC.
Remember that even though the National Electric Code may allow non- plenum cable, the final decision is up to your local Fire Marshall. Most cities adopt the national codes as their own without revision, but some cities modify or expand them and require plenum-rated cable in all situations. Regardless of the code or its interpretation, your Fire Marshall makes the final decision. We recommend that you contact your Fire Marshall if you have questions.
http://www.firemarshals.org/links/state-fire-marshals-websites/
Why is the regulation for plenum air spaces but not for inside the classroom?
It's dangerous to inhale fumes from any burning material. Communications cable is no more dangerous than any other plastic item you would find below the ceiling in a typical classroom — computers, carpet, power cords, etc. Therefore, requiring the use of plenum wires within the classroom itself would have little impact. The regulation covers the area where it's most critical.
How is plenum cable and innerduct different from CRM/PVC?
The Plenum rated coating on wire burns at a much higher temperature and emits fewer fumes.
What does plenum wire look like?
Identifying this cable just by looking at it is hard to tell. It is very similar in look and feel, so you'll want to check the print on the jacket for the letters "CMP"
Who sets the guidelines?
The National Electrical Code (NEC) is a set of guidelines recommending procedures to reduce the risk of fires, electric shock and other hazards associated with electrical installations. The code is advisory in nature, but most state and local building departments across the country use the NEC as the basis for their own electrical codes. Some local codes may be more restrictive, so please check with your local Fire Marshall if you're unsure.
Is compliance with the locally-adopted code mandatory?
Yes. City, county or state codes are mandatory and enforceable as law.
Make sure you and your contractor are on the same page. When life has been lost in a fire a lawsuit is not out of the question if plenum wire has not been installed when it should have been.
Read more »
According to the National Electric Code (NEC) a plenum is a "compartment or chamber to which one or more air ducts are connected and [which] forms part of the air distribution system." To qualify as a plenum, the space above an acoustic tile ceiling would have to extend above other rooms in the same building or be open to ducts connecting it to other parts of the building. The concern is that during a fire, if there is burning material in a plenum air space, smoke and fumes can travel through air ducts to the whole building. For this reason, there are codes to restrict the types of materials (such as wiring) that can be placed in the plenum.
It's quite common to have an acoustic tile ceiling without having a plenum. If your room-dividing walls extend above the dropped ceiling and seal off the space above, you do not have a plenum air space and so may not require plenum-rated wires. You can lift up an acoustical tile in your room and peek in to see if your room has a plenum.
What is the code?
According to the National Electric Code (NEC), in plenum air spaces you must use plenum rated cables, also called Communications Plenum Cable (CMP). Plenum cable is only required when cable is installed in a plenum air space. Materials kept below the ceiling — including speaker wire, computer cables, telephone cords, etc. — do not need to be plenum rated according to the NEC.
Remember that even though the National Electric Code may allow non- plenum cable, the final decision is up to your local Fire Marshall. Most cities adopt the national codes as their own without revision, but some cities modify or expand them and require plenum-rated cable in all situations. Regardless of the code or its interpretation, your Fire Marshall makes the final decision. We recommend that you contact your Fire Marshall if you have questions.
http://www.firemarshals.org/links/state-fire-marshals-websites/
Why is the regulation for plenum air spaces but not for inside the classroom?
It's dangerous to inhale fumes from any burning material. Communications cable is no more dangerous than any other plastic item you would find below the ceiling in a typical classroom — computers, carpet, power cords, etc. Therefore, requiring the use of plenum wires within the classroom itself would have little impact. The regulation covers the area where it's most critical.
How is plenum cable and innerduct different from CRM/PVC?
The Plenum rated coating on wire burns at a much higher temperature and emits fewer fumes.
What does plenum wire look like?
Identifying this cable just by looking at it is hard to tell. It is very similar in look and feel, so you'll want to check the print on the jacket for the letters "CMP"
Who sets the guidelines?
The National Electrical Code (NEC) is a set of guidelines recommending procedures to reduce the risk of fires, electric shock and other hazards associated with electrical installations. The code is advisory in nature, but most state and local building departments across the country use the NEC as the basis for their own electrical codes. Some local codes may be more restrictive, so please check with your local Fire Marshall if you're unsure.
Is compliance with the locally-adopted code mandatory?
Yes. City, county or state codes are mandatory and enforceable as law.
Make sure you and your contractor are on the same page. When life has been lost in a fire a lawsuit is not out of the question if plenum wire has not been installed when it should have been.
Industrial Cat5e Bulk Cable Solution for Mobile MRI Machines
Rick Dressel from Alliance HealthCare Services came to us looking for a solution to connect his mobile MRI machine to the clients Hospital. Alliance Imaging provides mobile MRI, PET/CT and CT, in addition to state-of-the-art dedicated breast MRI systems.
Rick had problems with previous cabling he was using. He started with a traditional solid conductor Cat5e PVC indoor cable. Unfortunately, over time he had to constantly replace these cables due to the repeated exposure to UV rays and harsh weather elements. In addition, the cable jacket was being torn up from repeated contact with the ground.
His next cable selection was a Cat5e solid direct burial cable. Although this cable is meant to stand up to the elements, it is gel filled, making working with this cable a hassle. The drag on different surfaces also eventually ate through the jacket.
We made the recommendation of using Datamax Extreme Cat5e Cable. This Quabbin 5730R cat5e cable has a polyurethane jacket, aluminum shield, and drain wire for superior harsh environment conditions. This cable uses a stranded conductor design, providing the flexibility Rick needed. Having sold this cable to production studios, we knew the DataMax Extreme cat5e cable would withstand the constant abuse. After having this cable installed on Rick's mobile MRI, here's what he had to say:
"Mr. Mercy Salinas, thank you for your expert knowledge in finding the perfect cat-5 cable, for our application. The Quabbin 5730R is exceeding far beyond expectations. I believe this cable will last in a outdoor environment for years. Any company using cat-5 in a outdoors environment, should try this cable. Thank you again for all of your help." - Rick Dressel
Related Posts:
Video: Bulk Cat5e Cable and Bulk Cat5e Shielded Cable
Video: How It's Made - Low Voltage Cable (Cat3, Cat5e, Cat6, OSP)
Video/Pictures: How to Terminate Cat5e and Cat6 Kwik Jacks
Update: UL Requires New Holographic Labels for Bulk Cable
Video/Pictures: How to Make Ethernet Cat5e Cables
Read more »
Rick had problems with previous cabling he was using. He started with a traditional solid conductor Cat5e PVC indoor cable. Unfortunately, over time he had to constantly replace these cables due to the repeated exposure to UV rays and harsh weather elements. In addition, the cable jacket was being torn up from repeated contact with the ground.
His next cable selection was a Cat5e solid direct burial cable. Although this cable is meant to stand up to the elements, it is gel filled, making working with this cable a hassle. The drag on different surfaces also eventually ate through the jacket.
We made the recommendation of using Datamax Extreme Cat5e Cable. This Quabbin 5730R cat5e cable has a polyurethane jacket, aluminum shield, and drain wire for superior harsh environment conditions. This cable uses a stranded conductor design, providing the flexibility Rick needed. Having sold this cable to production studios, we knew the DataMax Extreme cat5e cable would withstand the constant abuse. After having this cable installed on Rick's mobile MRI, here's what he had to say:
"Mr. Mercy Salinas, thank you for your expert knowledge in finding the perfect cat-5 cable, for our application. The Quabbin 5730R is exceeding far beyond expectations. I believe this cable will last in a outdoor environment for years. Any company using cat-5 in a outdoors environment, should try this cable. Thank you again for all of your help." - Rick Dressel
Related Posts:
Video: Bulk Cat5e Cable and Bulk Cat5e Shielded Cable
Video: How It's Made - Low Voltage Cable (Cat3, Cat5e, Cat6, OSP)
Video/Pictures: How to Terminate Cat5e and Cat6 Kwik Jacks
Update: UL Requires New Holographic Labels for Bulk Cable
Video/Pictures: How to Make Ethernet Cat5e Cables